Land Use Bylaw1P2007

Bylaw test

Top of page

Permitted use Rowhouse Building

a must have façade articulation for each Dwelling Unit, by including:
i a portion of a street facing façade of each unit recessed behind or projecting forward from the remainder of the street facing façade of that unit, with the projecting or recessed portion having a minimum dimension of:
A 2.0 metres in width;
B 0.3 metres in depth; and
C 2.4 metres in height; or
ii a porch that projects from a street facing façade a minimum dimension of:
A 2.0 metres in width; and
B 1.2 metres in depth;
b must have the main floor located above grade adjacent to the building to a maximum of 1.20 metres above grade for street facing façades;
c located on a corner parcel must have an exterior entrance which is visible from each street side of the corner parcel;
d must not have an attached private garage;
e must have a motor vehicle parking stall or private garage for each Dwelling Unit with direct, individual access to a lane;
f must not have windows on an exposed side façade of a unit that are located beyond the rear façade of a contextually adjacent building on an adjoining parcel unless:
i the window is located below the second storey;
ii (ii) the glass in the window is entirely obscured;
iii there is a minimum distance of 1.5 metres between the finished floor and the bottom of the window sill; or
iv the façade that contains the window is setback a minimum of 4.2 metres from the side property line;
g must not be located on a parcel where the difference between the average building reference points is greater than 2.4 metres; and
h must not be located on a parcel that is within a heritage guideline area.
2 deleted
3 Where not located on a corner parcel, the maximum building depth of a Rowhouse Building that is a permitted use in the R-CG District is the greater of:
a 60.0 percent of the parcel depth; or
4 deleted
5 To be a permitted use in the R-CG District a Rowhouse Building must not be located on a parcel that contains more than one main residential building.

DISCLAIMER: This version of Bylaw 1P2007 MUST NOT be relied upon; it is not an official version of the bylaw and may contain errors. The City of Calgary accepts no responsibility to persons relying solely on this information. Consult the Office of the City Clerk for an official version of the bylaw, if required. Please note that web pages are updated periodically.